Test Signal Generators
application: The portable or rack mount test signal generators are used to inject clean CW carriers into any broadband network. This offers the ability to perform amplifier alignment and evaluate overall system performance. They can provide up to 4 CW carriers from 5 MHz to 1 GHz with individual on/off and a level set window of 30 dB, not to exceed specified output levels.
features & benefits:
Carriers can be individually switched On or Off.
Carrier levels are individually set for system requirements.
1-4 carriers 5 MHz - 1GHz.
Clean carrier operation.
CATV compatible operating levels.
-20 dB test point.
High quality rugged construction.
Model: TSG-1000-R:
Dimensions: 1¾"W x 19"H x 6"DModel: TSG-4000-R:
Dimensions: 1¾"W x 19"H x 6"D
Model: TSG-4000-FP:
Dimensions: 8"W x 4"H x 10"Dtechnical specifications: Available Frequencies:
Number of Carriers:Any frequency from 5 MHz to 1GHz
1 to 4 1 to 4Maximum Output Level: 1 carrier +60 dBmV
2 carriers +57 dBmV
3-4 carriers +55 dBmVOutput Spurious:
RF Level Adjustment:
Output Level Accuracy:
Frequency Stability:
Connectors (RF):
Connectors (DC):
Impedance:>-65 dBc
30 dB
± 0.25 dB
± 200 kHz
F type
Screw 4 40 terminal block (TSG-4000-R only)
75 OhmsPowering:
TSG-4000-R:
TSG-4000-FP:
TSG-1000-R:
110 Vac 50/60 Hz fused or +24 or -48 Vdc fused (must be specified when ordering)
Internal battery pack with external AC adaptor
External AC adaptorSpecifications subject to change without notice
Sales, Product Information: sales@pcitech.org
Copyright © 1996 PCI Technologies Inc.